With multiple stocking facilities throughout the United States, Hammer & Steel has a large selection of steel sheet
piling products available for sale or rental. Our sheet piling products feature mechanical "ball and socket" connections
that allow each sheet to interlock with another and create a rigid barrier for earth and water while resisting the lateral
pressures of the these forces. The ball and socket interlock also permits flexibility in setting while remaining very
durable under driving conditions compared to other systems.
The Z shape of each section lends to its structural strength which is determined not only by the size, but also by the
thickness of the steel. Of course, the soil conditions in which the section is driven will also affect the performance
of the foundation or wall. The PZC and PZ series sheet pile can often be used as an alternative to Trade Arbed AZ sheet
piling from Arcelor.
High Efficiency"Z" Section Steel Sheet Pile
Per Single Section
Per Foot Of Wall
Section Designation
Nominal Width
Wall Depth (Height)
Web Thickness
Flange Thickness
Area
Weight Per Foot
Moment of Inertia
Section Modulus
Total Surface Area
Nominal Coating Area
Area
Weight Per Foot
Moment of Inertia
Section Modulus
in.
in.
in.
in.
in.2
lbs/ft
in.4
in.3
ft2/ft
ft2/ft
in2/ft
lbs/ft2
in4/ft
in3/ft
PZC™12
27.88
12.52
0.335
0.335
13.64
46.4
326.6
52.0
6.09
5.60
5.87
20.0
140.6
22.4
PZC™13
27.88
12.56
0.375
0.375
14.82
50.4
353.0
56.2
6.09
5.60
6.38
21.7
152.0
24.2
PZC™14
27.88
12.60
0.420
0.420
16.15
55.0
382.7
60.5
6.09
5.60
6.95
23.7
164.8
26.0
PZC™17
25.00
15.21
0.335
0.335
13.64
46.4
492.9
64.5
6.09
5.60
6.55
22.3
236.6
31.0
PZC™18
25.00
15.25
0.375
0.375
14.82
50.4
532.2
69.8
6.09
5.60
7.12
24.2
255.5
33.5
PZC™19
25.00
15.30
0.420
0.420
16.16
55.0
576.5
75.2
6.09
5.60
7.76
26.4
276.7
36.1
All Dimensions Are Nominal
Heavy Duty "Z" Section Sheet Pile
Per Single Section
Per Foot Of Wall
Section Designation
Nominal Width
Wall Depth (Height)
Web Thickness
Flange Thickness
Area
Weight Per Foot
Moment of Inertia
Section Modulus
Total Surface Area
Nominal Coating Area
Area
Weight Per Foot
Moment Of Inertia
Section Modulus
in.
in.
in.
in.
in.2
lbs/ft
in.4
in.3
ft2/ft
ft2/ft
in.2/ft
lbs/ft2
in.4/ft
in.3/ft
PZ 22
22
9.25
0.375
0.375
12.2
41.5
156
33.7
4.96
4.46
6.65
22.6
85.1
18.4
PZ 27
18
12.1
0.375
0.375
12.2
41.5
281
46.4
4.96
4.46
8.13
27.7
187.3
31
PZ 35
22.64
15.1
0.5
0.605
19.4
66
697
92.3
5.83
5.33
10.28
35
369.4
48.9
PZ 40
19.69
16.4
0.5
0.6
19.28
65.6
824.8
100.6
5.83
5.33
11.75
40
502.7
61.3
All Dimensions Are Nominal
Flat Sections
Typically used for circular cell design applications, flat sheet pile is a proven technology that is still used on many
projects. While these sheet piles offer much less beam strength than Z piles, the sections use a Thumb and Finger interlock
with a three-point contact connection to generate significant pull strength to counter the hoop stress applied to them.
Per Single Section
Per Foot Of Wall
Section Designation
Nominal Width
Web Thickness
Weight Per Foot
Moment of Inertia
Section Modulus
Nominal Coating Area
Weight Per Foot
Moment Of Inertia
Section Modulus
in.
in.
lbs/ft
in.4
in.3
ft2/ft
lbs/ft2
in.4/ft
in.3/ft
PS 27.5
19.69
0.4
45.2
5
3.2
3.68
27.5
3
1.9
PS 31.0
19.69
0.5
50.9
5
3.2
3.68
31
3
1.9
All Dimensions Are Nominal
Company Headquarters
Branch Offices
11916 Missouri Bottom Rd.
St. Louis, MO 63042
Ph: 800.325.PILE (7453)
Ph: 314.895.4600
Fx: 314.895.4070