Bearing Capacity Chart -- Delmag Diesel Pile Hammers

Delmag D8-22 Single Acting Diesel Pile Hammer


Blows
Piston
Hammer
Bearing Capacity ( tons ) for a Pile Set ( blows / in ) of:
Per
Min.
Stroke
(ft)
Energy
(ft-lbs)
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
54
4.65
8193
53
61
67
72
77
81
85
88
91
94
96
99
101
103
105
107
108
53
4.84
8528
55
63
69
75
79
84
87
91
94
96
99
102
104
106
108
110
112
52
5.04
8880
57
65
72
77
82
86
90
94
97
99
102
105
107
109
111
113
115
51
5.25
9251
59
68
74
80
85
89
93
96
100
103
105
108
110
112
114
116
118
50
5.47
9638
62
70
77
83
88
92
96
100
103
106
108
111
113
116
118
120
122
49
5.71
10061
64
73
80
86
91
95
99
103
106
109
112
115
117
119
122
124
126
48
5.97
10519
67
75
83
89
94
98
102
106
110
113
116
118
121
123
125
127
129
47
6.24
10995
69
78
86
92
97
102
106
110
113
116
119
122
125
127
129
131
133
46
6.52
11488
72
81
89
95
100
105
109
113
117
120
123
126
128
131
133
135
138
45
6.83
12034
75
84
92
98
104
109
113
117
121
124
127
130
133
135
138
140
142
44
7.16
12616
78
87
95
102
107
112
117
121
125
128
131
134
137
140
142
144
147
43
7.51
13233
81
91
99
105
111
116
121
125
129
132
136
139
142
144
147
149
151
42
7.88
13885
84
94
102
109
115
120
125
129
133
137
140
143
146
149
151
154
156
41
8.29
14607
88
98
106
113
119
125
130
134
138
142
145
148
151
154
157
159
162
40
8.72
15365
91
102
110
117
124
129
134
139
143
147
150
153
156
159
162
165
167
39
9.19
16193
95
106
114
122
128
134
139
144
148
152
155
159
162
165
168
170
173
38
9.70
17091
99
110
119
127
133
139
144
149
153
157
161
164
168
171
174
176
179
37
10.25
18061
103
114
124
132
138
144
150
155
159
163
167
170
174
177
180
183
185
36
10.84
19100
107
119
129
137
144
150
155
160
165
169
173
177
180
183
186
189
192
35
11.48
20228
112
124
134
142
149
156
161
167
171
176
180
183
187
190
193
196
199

Calculates bearing capacities based upon FHWA modified Gates formula:
Ru = 0.5 [ 1.75 √E ( log 10N ) - 100 ]
where
Ru = Driven bearing capacity of the pile in tons
N = Number of hammer blows ber inch
E = Energy developed by the hammer per blow in ft-lbs


 
 
Company Headquarters Branch Offices
11916 Missouri Bottom Rd.
St. Louis, MO 63042
Ph: 800.325.PILE (7453)
Ph: 314.895.4600
Fx: 314.895.4070
Benicia, California
Ph: 877.224.3356

Boston, Massachusetts
Ph: 508-419-7374
Green Cove Spring, Florida
Ph: 904.284.6800

Houston, Texas
Ph: 281.852.1136
Kansas City, Kansas
Ph: 913.681.9295

Minneapolis, Minnesota

Ph: 952.469.6060


Hammer & Steel