Delmag D12-32 & D12-42 Single Acting Diesel Pile Hammers
Blows | Piston | Hammer | Bearing Capacity (tons) for a Pile Set (blows/in) of: | ||||||||||||||||
Per Min. | Stroke (ft) | Energy (ft-lbs) | 2.0 | 2.5 | 3.0 | 3.5 | 4.0 | 4.5 | 5.0 | 5.5 | 6.0 | 6.5 | 7.0 | 7.5 | 8.0 | 8.5 | 9.0 | 9.5 | 10.0 |
54 | 4.65 | 13113 | 80 | 90 | 98 | 105 | 111 | 116 | 120 | 124 | 128 | 132 | 135 | 138 | 141 | 143 | 146 | 148 | 150 |
53 | 4.84 | 13649 | 83 | 93 | 101 | 108 | 114 | 119 | 124 | 128 | 132 | 135 | 139 | 142 | 145 | 147 | 150 | 152 | 154 |
52 | 5.04 | 14213 | 86 | 96 | 104 | 111 | 117 | 122 | 127 | 132 | 135 | 139 | 142 | 146 | 149 | 151 | 154 | 156 | 159 |
51 | 5.25 | 14805 | 89 | 99 | 107 | 114 | 121 | 126 | 131 | 135 | 139 | 143 | 146 | 150 | 153 | 155 | 158 | 161 | 163 |
50 | 5.47 | 15425 | 91 | 102 | 111 | 118 | 124 | 130 | 135 | 139 | 143 | 147 | 151 | 154 | 157 | 160 | 162 | 165 | 167 |
49 | 5.71 | 16102 | 94 | 105 | 114 | 121 | 128 | 134 | 139 | 143 | 147 | 151 | 155 | 158 | 161 | 164 | 167 | 170 | 172 |
48 | 5.97 | 16835 | 98 | 109 | 118 | 125 | 132 | 138 | 143 | 148 | 152 | 156 | 159 | 163 | 166 | 169 | 172 | 175 | 177 |
47 | 6.24 | 17597 | 101 | 112 | 121 | 129 | 136 | 142 | 147 | 152 | 156 | 160 | 164 | 168 | 171 | 174 | 177 | 180 | 182 |
46 | 6.52 | 18386 | 104 | 116 | 125 | 133 | 140 | 146 | 152 | 156 | 161 | 165 | 169 | 172 | 176 | 179 | 182 | 185 | 187 |
45 | 6.83 | 19261 | 108 | 120 | 129 | 138 | 145 | 151 | 156 | 161 | 166 | 170 | 174 | 178 | 181 | 184 | 187 | 190 | 193 |
44 | 7.16 | 20191 | 112 | 124 | 134 | 142 | 149 | 156 | 161 | 166 | 171 | 175 | 179 | 183 | 187 | 190 | 193 | 196 | 199 |
43 | 7.51 | 21178 | 116 | 128 | 138 | 147 | 154 | 161 | 166 | 172 | 176 | 181 | 185 | 189 | 192 | 196 | 199 | 202 | 205 |
42 | 7.88 | 22222 | 120 | 132 | 143 | 151 | 159 | 166 | 172 | 177 | 182 | 186 | 191 | 195 | 198 | 202 | 205 | 208 | 211 |
41 | 8.29 | 23378 | 124 | 137 | 148 | 157 | 164 | 171 | 177 | 183 | 188 | 193 | 197 | 201 | 205 | 208 | 211 | 215 | 218 |
40 | 8.72 | 24590 | 129 | 142 | 153 | 162 | 170 | 177 | 183 | 189 | 194 | 199 | 203 | 207 | 211 | 215 | 218 | 221 | 224 |
39 | 9.19 | 25916 | 133 | 147 | 158 | 167 | 176 | 183 | 189 | 195 | 200 | 205 | 210 | 214 | 218 | 222 | 225 | 229 | 232 |
38 | 9.70 | 27354 | 138 | 152 | 164 | 173 | 182 | 189 | 196 | 202 | 207 | 212 | 217 | 221 | 225 | 229 | 233 | 236 | 239 |
37 | 10.25 | 28905 | 144 | 158 | 170 | 180 | 188 | 196 | 203 | 209 | 215 | 220 | 224 | 229 | 233 | 237 | 241 | 244 | 248 |
36 | 10.84 | 30569 | 149 | 164 | 176 | 186 | 195 | 203 | 210 | 216 | 222 | 227 | 232 | 237 | 241 | 245 | 249 | 253 | 256 |
35 | 11.48 | 32374 | 155 | 170 | 183 | 193 | 202 | 210 | 217 | 224 | 230 | 235 | 240 | 245 | 250 | 254 | 258 | 261 | 265 |
Calculates bearing capacities based upon FHWA modified Gates formula:
Ru = 0.5 [ 1.75 √E ( log 10N ) - 100 ]
where
Ru = Driven bearing capacity of the pile in tons
N = Number of hammer blows per inch
E = Energy developed by the hammer per blow in ft-lbs