The Dual Auger Casing Drive is ideal for drilling operations that are directly against adjacent structures (contiguous type,
tangential, secant and on-the-wall) and for soilmix applications.
In most cases a secant pile wall is installed with a resonance-free VDW (in front of the wall) procedure and will serve as
the foundation for the building. Typical areas of application are underground parking garages and rainwater retention basins.
In addition to secant pile walls, contiguous and tangential pile walls, single piles can also be installed with this unit. Onto the VDW
double auger head system a casing and drilling head are attached. The tools turn in opposite directions and
the position of the auger head can be adjusted depending upon soil conditions. While pulling, the tools concrete is pumped
into the bore hole, creating the pile. Double auger heads also serve as a tool for soil exchange procedures and full displacement piles.
Dual Auger/Casing Drive
Model 35/25
Model 60/35
Model 12/06
Torque Auger Drive
kNm ft. lbs.
25 18,430
35 25,800
60 44,230
Torque Casing Drive
kNm ft. lbs.
35 25,800
60 44,230
120 88,475
Center Shaft ID
mm in.
100 4
100 4
100 4
Max Casing Diameter
mm in.
406 16
610 24
914 36