Delmag D46-32 Single Acting Diesel Pile Hammer
Blows | Piston | Hammer | Bearing Capacity ( tons ) for a Pile Set ( blows / in ) of: | ||||||||||||||||
Per Min. | Stroke (ft) | Energy (ft-lbs) | 2.0 | 2.5 | 3.0 | 3.5 | 4.0 | 4.5 | 5.0 | 5.5 | 6.0 | 6.5 | 7.0 | 7.5 | 8.0 | 8.5 | 9.0 | 9.5 | 10.0 |
54 | 4.65 | 47165 | 197 | 216 | 231 | 243 | 254 | 264 | 273 | 281 | 288 | 295 | 301 | 306 | 312 | 317 | 321 | 326 | 330 |
53 | 4.84 | 49092 | 202 | 221 | 236 | 249 | 261 | 271 | 279 | 287 | 295 | 301 | 308 | 314 | 319 | 324 | 329 | 333 | 338 |
52 | 5.04 | 51121 | 207 | 227 | 242 | 255 | 267 | 277 | 286 | 294 | 302 | 309 | 315 | 321 | 327 | 332 | 337 | 341 | 346 |
51 | 5.25 | 53251 | 213 | 232 | 248 | 262 | 273 | 284 | 293 | 301 | 309 | 316 | 323 | 329 | 334 | 340 | 345 | 349 | 354 |
50 | 5.47 | 55482 | 218 | 238 | 254 | 268 | 280 | 291 | 300 | 309 | 316 | 324 | 330 | 336 | 342 | 348 | 353 | 358 | 362 |
49 | 5.71 | 57917 | 224 | 244 | 261 | 275 | 287 | 298 | 308 | 316 | 324 | 332 | 339 | 345 | 351 | 356 | 362 | 366 | 371 |
48 | 5.97 | 60554 | 230 | 251 | 268 | 282 | 295 | 306 | 316 | 325 | 333 | 340 | 347 | 354 | 360 | 365 | 371 | 376 | 381 |
47 | 6.24 | 63292 | 236 | 258 | 275 | 290 | 303 | 314 | 324 | 333 | 341 | 349 | 356 | 363 | 369 | 375 | 380 | 385 | 390 |
46 | 6.52 | 66132 | 243 | 265 | 282 | 297 | 310 | 322 | 332 | 342 | 350 | 358 | 365 | 372 | 378 | 384 | 390 | 395 | 400 |
45 | 6.83 | 69277 | 250 | 272 | 290 | 306 | 319 | 331 | 341 | 351 | 360 | 368 | 375 | 382 | 388 | 394 | 400 | 405 | 411 |
44 | 7.16 | 72624 | 257 | 280 | 298 | 314 | 328 | 340 | 351 | 360 | 369 | 377 | 385 | 392 | 399 | 405 | 411 | 416 | 422 |
43 | 7.51 | 76174 | 264 | 288 | 307 | 323 | 337 | 349 | 360 | 370 | 379 | 388 | 396 | 403 | 410 | 416 | 422 | 428 | 433 |
42 | 7.88 | 79927 | 272 | 296 | 315 | 332 | 346 | 359 | 370 | 381 | 390 | 398 | 406 | 414 | 421 | 427 | 433 | 439 | 445 |
41 | 8.29 | 84085 | 280 | 305 | 325 | 342 | 356 | 369 | 381 | 392 | 401 | 410 | 418 | 426 | 433 | 440 | 446 | 452 | 457 |
40 | 8.72 | 88447 | 289 | 314 | 334 | 352 | 367 | 380 | 392 | 403 | 413 | 422 | 430 | 438 | 445 | 452 | 459 | 465 | 470 |
39 | 9.19 | 93214 | 298 | 323 | 345 | 362 | 378 | 392 | 404 | 415 | 425 | 434 | 443 | 451 | 458 | 465 | 472 | 478 | 484 |
38 | 9.70 | 98387 | 307 | 334 | 355 | 374 | 390 | 404 | 416 | 428 | 438 | 448 | 456 | 465 | 472 | 480 | 486 | 493 | 499 |
37 | 10.25 | 103966 | 317 | 344 | 367 | 386 | 402 | 416 | 429 | 441 | 452 | 461 | 471 | 479 | 487 | 494 | 501 | 508 | 514 |
36 | 10.84 | 109950 | 327 | 356 | 379 | 398 | 415 | 430 | 443 | 455 | 466 | 476 | 485 | 494 | 502 | 510 | 517 | 524 | 530 |
35 | 11.48 | 116442 | 338 | 367 | 391 | 411 | 428 | 444 | 457 | 470 | 481 | 491 | 501 | 510 | 518 | 526 | 533 | 541 | 547 |
| Calculates bearing capacities based upon FHWA modified Gates formula: Ru = 0.5 [ 1.75 √E ( log 10N ) - 100 ] where Ru = Driven bearing capacity of the pile in tons N = Number of hammer blows per inch E = Energy developed by the hammer per blow in ft-lb |